MALLINKRODT-BAKER -- 2186 HYDROGEN PEROXIDE 30% -- 6810-00-233-1711
===================== Product Identification ===================== Product ID:2186 HYDROGEN PEROXIDE 30% MSDS Date:03/01/1997 FSC:6810 NIIN:00-233-1711 === Responsible Party === Company Name:MALLINKRODT-BAKER Address:222 RED SCHOOL LANE City:PHILLIPSBURG State:NJ ZIP:08865-2219 Country:US Info Phone Num:908-859-2151/800-582-2537 Emergency Phone Num:908-859-2151/800-424-9300(CHEMTREC) CAGE:EO303 === Contractor Identification === Company Name:MALLINCKRODT BAKER, INC. Address:222 RED SCHOOL LANE Box:City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Phone:800-582-2537 CAGE:70829 Company Name:MALLINKRODT-BAKER (FORMALLY J.T. BAKER COMPANY) Address:222 RED SCHOOL LANE Box:NONE City:PHILLIPSBURG State:NJ ZIP:08865-2219 Country:US Phone:800-582-2537 EXT 6501/908-859-2151 CAGE:EO303 ============= Composition/Information on Ingredients ============= Ingred Name:HYDROGEN PEROXIDE (SARA 302) CAS:7722-84-1 RTECS #:MX0900000 Fraction by Wt: 29-32% Other REC Limits:NONE RECOMMENDED OSHA PEL:1 PPM ACGIH TLV:1 PPM; 9596 Ingred Name:WATER CAS:7732-18-5 RTECS #:ZC0110000 Fraction by Wt: 68-71% Other REC Limits:NONE RECOMMENDED ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INHAL:VAP CORRO,IRRIT RESP TRACT.MIST MAY BURN MUC MEMBRANE OF NOSE/THROAT.IN SEVERE CASES EXPO MAY RESULT IN PULM EDEMA/DEATH.INGEST:CORR/IRRIT MOUTH/THROAT/ABDOMEN.LG DOSES MAY CAUSE SYMPT OF ADN PA IN,VOMIT,DIARR,BLISTERING/TISSUE DESTRUCTION.STOMACH DISTENTION(DUE TO RAPID LIBERATION OXY)RISK OF STOMACH(SIGN/SYMPTO) Explanation of Carcinogenicity:PER MSDS:CARCINOGEN:IARC/NTP:NO. Effects of Overexposure:HEALTH:PERFORATION,CONVULS,PULM EDEMA,COMA,POSSIBLE CEREBRAL EDEMA,DEATH.SKIN:CORR-REDNESS,PAIN,SEVERE BURN CAN OCCUR.EYE:VAP VERY CORR,IRRIT EYES.SYMPT-PAIN,REDNESS,BLURR VISION.SPLASHES CAN CAUSE PE RM TISSUE DESTRUCTION.CHRONIC:NO INFO FOUND. SIGN/SYMPTOMS SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:PERSONS W/PRE-EXISTING SKIN DISORDERS OR EYE PROBELMS OR IMPAIRED RESPIRATORY FUNCTION MAY BE MORE SUSCEPTIBLE TO EFFECTS OF SUBSTANCE. ======================= First Aid Measures ======================= First Aid:INHAL:REMOVE TO FRESH AIR.NOT BREATH GIVE ART RESP;BREATH DIFFI GIVE OXY.GET MED ATTN IMMED.INGEST:DONT INDUCE VOMIT.GIVE LG QUANT OF H2O.NEVER GIVE ANYTHING BY MOUTH IF UNCONSC.GET MED ATTN IMMED.SKI N:IMMED FLUSH W/PLENTY OF H2O FOR @LEAST15MINS WHILE REMOVE CONTAM CLOTH/SHOES.GET MED ATTN.EYE:IMMED FLUSH W/PLENTY OF H2O FOR @LEAST 15MINS,LIFTING LOWER/UPPER EYELIDS OCCASIONALLY.GET MED (SUPPL) ===================== Fire Fighting Measures ===================== Flash Point:NP Autoignition Temp:Autoignition Temp Text:NP Lower Limits:NP Upper Limits:NP Extinguishing Media:WATERSPRAY MAY BE USED TO EXT SURROUNDING FIRE & COOL EXPO CNTNR.WATERSPRAY WILL ALSO REDUCE FUME/IRRIT GASES. Fire Fighting Procedures:IN EVENT OF FIRE WEAR FULL PROTECTIVE CLTOHING & NIOSH-APPROV SELF-CONTAINED BREATHING APPARATUS W/FULL FCPIECE OPERATED IN PRESSURE DEMAND/OTHER +PRESS MODE. Unusual Fire/Explosion Hazard:NOT COMBUSTIBLE-SUBST STRONG OXIDIZIER;ITS HEAT OF RX W/RED AGENTS/COMBUST MAY CAUSE IGN,INCR FLAMM OF COMBUST,ORGANIC,READILY OXIDIZABLE MATLS.CONTACT W/(SUPP) ================== Accidental Release Measures ================== Spill Release Procedures:CAUT:CAUSTIC MATL.CAUSES FIRE W/ORG MATL.VENTI AREA.WEAR APPORPR PPE.CONTAIN/RECOVER.DONT RTN TO ORIG CNTNR.LG:DIL W/LOTS OF H2O.HOLD IN POND/DIKE TIL PEROXIDE DECOMPO,THEN DISCHARGE INTO SUITABLE TRE AT SYS.NEUTRA AFT DIL TO 5-10% PEROXIDES(OTH PREC) Neutralizing Agent:SODIUM METABISULFITE OR SODIUM SULFITE. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN COO(<35C)WELL VENTI DARK AREA SEPARATED FRM COMBUST/RED AGENT/STRONG BASES/ORG.DONT STORE ON WOODEN SHELVED/FLOORS.ROTATE STOCK.VENT CNTNR. Other Precautions:STORAGE COLOR CODE:YELLOW(REACTIVE).IF MATL DRY ON CLOTH EVAPO LEADS TO CONCEN/INCR IGN. SPILL:DONT FLUSH UNDIL TO SEWER.CAN INCR FLAMM OF ADJACENT COMBUST MATLS.EMPTY CNTNR SHOULD BE RINSE W/H2O BEF DISCARDING. SARA RQ:1000LBS.CERCLA ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH APPROV.IF EXPO LIMIT EXCEEDED WEAR SUPPLIED AIR FULL-FACEPIECE RESP.AIRLINED HOOOD,OR FULL-FCPIECE SELF-CONTAINED BREATHING APPARATUS.THIS SUBSTANCE HAS UNK WARNING PROPERTIES. Ventilation:LOC &/OR GEN EXHAUT RECOMMENDED.PREFER LOC EXHAU VENTI-CNTRL CONTAM EMISSIONS @SOURCE.REF:ACGIH"INDUSTR VENTI,MANUAL..." Protective Gloves:IMPERV GLOVES Eye Protection:CHEM SAF GOGG,FULL FACE SHIELD. Other Protective Equipment:EYEWASH FOUNTAIN,QUICK-DRENCH FACI IN WORKAREA.IMPERV PROT CLOTH,BOOTS,LAB COAT,APRON,COVERALLS AS APPROPRIATE. Work Hygienic Practices:WASH CONTAM CLOTH BEF REUSE;CLEAN WELL SHOES BEF REULSE.CHECK PERIODICALLY FOR BULGING CNTNR.PROTECT FRM PHYS DMG. Supplemental Safety and Health 1STAID:ATTN IMMED.NOTE TO DR:PULM EDEMA MAY BE DELAY 24-48HRS.KEEP UNDER OBSERV.GASTRIC LAVAGE MAY BE NECESSARY IF INGEST.ANALYSIS OF BODY FLUIDS(GASTRIC ASPIRATES)W/TICL2 RX DONE IMMED REVEALS PEROXI DES. FIRE/EXPLO:OXIDIZ SUBST CAUSE EXT VIOL COMBUST.DRY CONCEN H2O2 ON CLOTH/COMBUST CAUSE FIRE/EXPLO.SEAL CNTNR RUPTURE ================== Physical/Chemical Properties ================== HCC:D3 Boiling Pt:B.P. Text:226F,108C Melt/Freeze Pt:M.P/F.P Text:-13F,-25C Decomp Temp:Decomp Text:NP Vapor Pres:25 @30C Vapor Density:1.17 Spec Gravity:NP pH:3.3 Viscosity:NP Evaporation Rate & Reference:<1, BUTYL ACETATE=1 Solubility in Water:INFINITELY SOLUBLE Appearance and Odor:CLEAR, COLORLESS LIQUID, SLIGHT ACRID ODOR Percent Volatiles by Volume:100 Corrosion Rate:NP ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES HEAT,RED AGENTS,ORG MATLS,DIRT,ALKALIS,RUST,MANY METALS.SPONT COMBUST ON STANDING IN CONTACT W/READILY FLAMM MATL. Stability Condition to Avoid:SLOWLY DECOMP-RELEASES OXY.UNSTABLE W/HEAT,RESULT IN DANGEROUS PRESSURES.STRONG OXIDIZER.AVOID LIGHT,KEEP CLSD BUT VENT. Hazardous Decomposition Products:DECOMPOSES TO H2O & OXY W/RAPID HEAT RELEASE.USE VENTED CNTNRS.SOLN CAN DECOMPOSE VIOLENTLY UPON HEATING. ==================== Disposal Considerations ==================== Waste Disposal Methods:WHATEVER CANT BE SAVE FOR RECOV/RECYC HNDL AS HAZ WASTE,SENT TO RCRA APPROV WASTE FACI.PROD PROCESS/USE/CONTAM MAY CHANGE WASTE MNGMT OPTS.STATE/LOC REGS MAY DIFFER FRM FED.DIL W/H2O,FLUSH TO SEWER IF LOC REGS ALLOW.CNTNR DISPO IAW FED/ST/LOC REGS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.