VISTA PAINT CORP -- 4000 UNIPRIME -- 8010-00N021431
=====================  Product Identification  =====================

Product ID:4000 UNIPRIME
MSDS Date:06/16/1988
FSC:8010
NIIN:00N021431
=== Responsible Party ===
Company Name:VISTA PAINT CORP
Address:2020 E ORANGETHORPE AVE
City:FULLERTON
State:CA
ZIP:92631
Country:US
Info Phone Num:714-680-3800
Emergency Phone Num:714-680-3800
CAGE:0C4T4
=== Contractor Identification ===
Company Name:VISTA PAINT CORP
Address:2020 E ORANGETHORPE AVE
Box:City:FULLERTON
State:CA
ZIP:92631
Country:US
Phone:714-680-3800
CAGE:0C4T4

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYLENE GLYCOL  (SARA III)
CAS:107-21-1
RTECS #:KW2975000
OSHA PEL:C 50 PPM
ACGIH TLV:C 50 PPM,VAPOR; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:AMMONIA  (SARA III)
CAS:7664-41-7
RTECS #:BO0875000
OSHA PEL:50 PPM
ACGIH TLV:25 PPM/35 STEL; 9293
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:PROPIONIC ACID, 2-METHYL-, MONOESTER WITH
    2,2,4-TRIMETHYL-1, 3-PENTANEDIOL; (TEXANOL)
CAS:25265-77-4
RTECS #:UF6000000

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH VAPOR
    CONCENTRATIONS MAY HAVE RESULTS RANGING FROM DIZZINESS AND
    HEADACHES TO UNCONSCIOUSNESS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:DRINK WATER TO DILUTE. DO NOT INDUCE VOMIT.
    INHAL:REMOVE TO FRESH AIR. SKIN:WASH W/SOAP & WATER. EYES:FLUSH W/
    WATER FOR AT LEAST 15 MINUTES OR UNTIL IRRITATION SUBSIDES.

=====================  Fire Fighting Measures  =====================

Flash Point:248F,120C
Lower Limits:0.62%
Upper Limits:4.24%
Extinguishing Media:FOAM, CO2, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP AWAY FROM HEAT. CONTAINERS MAY
    EXPLODE WHEN EXPOSED TO EXTREME HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CLEAN SPILLS IMMEDIATELY WITH ABSORBANT SUCH
    AS CLAY OR SAND.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT OR FLAME.
Other Precautions:AVOID UNNECESSARY EXPOSURE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AVOID EXCESSIVE VAPOR INHALATION. USE NIOSH/MSHA
    APPROVED RESPIRATOR IF TLV IS EXCEEDED.
Ventilation:MECHANICAL VENTILATION MAY BE USED IF NEEDED TO CONTROL
    MIST OR VAPOR.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FCSHLD.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:250F,121C
Vapor Pres:0.02 MM HG
Spec Gravity:1.334
Solubility in Water:YES
Appearance and Odor:LIQUID, MILD ODOR.
Percent Volatiles by Volume:60

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:CONTACT WITH STRONG OXIDIZERS.
Hazardous Decomposition Products:CO2.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.